Shaun Merrigan's Information Pages


News


YouTube Stops Working on older iPad

Tech, Troubleshooting. Comments Off on YouTube Stops Working on older iPad

10th February

I have an older iPad Mini2 (Model A1489) running iPadOS 12.5.7. For the past year or so the YouTube app has been constantly asking me to update as follows:

YouTube is out of date (popup):

Update to continue

Click to Update

Cannot Update

Cancel

Continue using YouTube app

By cancelling, I have been able to continue running the YouTube app and ignore the update prompt. However, last week, I could not bypass the update prompt:

Update to continue

Click to update

Cannot update, download older version?

Cannot download older version

No option to cancel, so GOTO 1

The update prompt stated that iOS 14 or newer was needed to install the new YouTube app, but since my older Mini2 is fixed on 12.5.7, I could never do the update. The YouTube app was stuck in the update loop, so I could not use it.

This iPad is behind a … Read More »


Tektronix SG5010 Audio Signal Generator Repair

Audio, Electronics, Test Equipment. Comments Off on Tektronix SG5010 Audio Signal Generator Repair

14th December

Background

The Tektronix SG5010 is an audio signal generator plug-in for the TM5000 modular test equipment system. It can generate five waveforms: sine wave, square wave, SMPTE/DIN intermodulation test signal, CCIF intermodulation test signal, and sine wave burst. All these signals may be swept in frequency and amplitude. It can generate very low distortion (THD+N < 0.0008%; my own measurements) sine waves from 20Hz-20kHz. It is CPU controlled with selections made via GPIB or front panel keyboard. These characteristics made it very desirable as part of an audio amplifier test lab. These units command a high price: Several working units have recently (Dec 2023) been sold for $USD 1500.

I recently acquired a non-working SG5010 for a good price. This post documents my efforts (ultimately successful) in getting it working.

Tektronix SG5010 Overview

Tektronix SG5010 Front Panel

First … Read More »


Tektronix CG5001 Calibration Generator Repair

Electronics, Test Equipment. Comments Off on Tektronix CG5001 Calibration Generator Repair

12th December

The document describes the repair process of a Tektronix CG5001 Calibration Generator. It discusses the errors encountered during the power-up self-test and the components that were found to be faulty. The document also mentions the use of extender cables during the diagnostic and repair process.


Analysis of Sprague 672D Capacitor Failures in vintage HP Test Equipment

Electronics, Restoration, Test Equipment. Comments Off on Analysis of Sprague 672D Capacitor Failures in vintage HP Test Equipment

28th November

Shaun Merrigan investigated Sprague 672D Electrolytic capacitor failures in the HP 70000 MMS test equipment. He found that due to thousands of hours of running time and high internal temperatures, many capacitors have failed. The capacitors made before 1990 are highly prone to failure, while those made between 1990-1999 show signs of aging. He replaced the faulty capacitors with Chemi-Con KYA and KZN series capacitors and all modules are now functioning properly.


HP 70100A Power Meter Rubber Pad Replacement

Electronics, Restoration, Tech, Test Equipment. Comments Off on HP 70100A Power Meter Rubber Pad Replacement

24th November

The Hewlett Packard 70100A is the power meter module in the HP 70000 modular test system. This post will document a problem common to three 70100A units I have recently restored.

As part of the restoration process, I opened the modules to perform a visual inspection. What I found under the outer cover was this:

70100A PS CPU Board Solder Side Overview before repair

HP 70100A PS CPU Board Deteriorated Rubber Pads

HP 70100A PS CPU Board Deteriorated Rubber Pads

HP 70100A PS CPU Board Deteriorated Rubber Pads

HP 70100A PS CPU Board Deteriorated Rubber Pads

The rubber spacer pads between the circuit boards and the outer metal cover had deteriorated to the point of liquifying and running down board via gravity. All the pads in the three units I examined were afflicted to some degree. Several years ago, I documented a similar phenomenon … Read More »


Tektronix 284 Pulse Generator Repair

Electronics, Restoration, Test Equipment. Comments Off on Tektronix 284 Pulse Generator Repair

21st November

This post will document my recent repair of a Tektronix 284 Pulse Generator. This device was introduced by Tektronix in 1967. It can produce:

A 50kHz, 200mv fast risetime pulse. Typically, tr < 70 ps

A 100 kHz, 1 MHz, or 10 MHz square wave at 10, 100, or 1000 mV

A 100 MHz or 1 GHz sine wave at 100 mV

The Tektronix 284 can be used to check the risetime of oscilloscopes, (both sampling and real time) amplifiers, transistors, transient responses, and for TDR work. The pulses are generated by a tunnel diode which is a semiconductor device capable of changing states very quickly. Tunnel diodes were invented in the late 1950’s in Japan and widely used in test equipment through the 1970’s. Tektronix used tunnel diodes in “pulsers” like the 284 and many oscilloscopes including the … Read More »


HP 70001A Power Supply Refresh

Electronics, Test Equipment, Troubleshooting. Comments Off on HP 70001A Power Supply Refresh

17th November

I have recently begun to restore several pieces of Hewlett Packard 70000 Series MMS (Modular Measurement System) equipment. The basic component of the system is a power and/or display frame which can house various test equipment modules. This post documents my restoration of the HP 70001A Power Supply.

The Hewlett Packard 70000 MMS is a high-performance, modular measurement system for RF, microwave, and Lightwave measurements. The MMS instruments include spectrum analyzers, signal generators, power meters, DMM, digital oscilloscope, counter, and more. The system is assembled by inserting the appropriate modules into a mainframe (which supplies power, cooling, and communication) along with a display.

Historically, the 70000 MMS system was introduced in 1986 and continued to be available through at least 2001 (based on HP/Agilent catalogs). The latest prices (1993) I could find for a couple of representative HP 70000 systems follows (all … Read More »


Vacuum Tube Tester: The Roetest

Electronics, Tech, Test Equipment, Vacuum Tubes. Comments Off on Vacuum Tube Tester: The Roetest

17th March

I recently completed the construction of a PC controlled vacuum tester: The Roetest. This is a computer-controlled tube tester which works as follows:

Using the PC software, load the tube data from the extensive database

Verify the tube data and pinout on the screen; the tester configures the pin connections automatically

Run the tests for shorts and filament continuity

Run the required tests

Test the tube at full voltage and current (not a pulse test)

Save the result

Add the tube and test data to inventory

Roetest V10 Front Panel and case

Roetest V10 Main board and plug in boards

Roetest V10 Front Panel

Construction Details:

4600 Solder Joints

600+ Components

20 separate circuit boards

Mechanical work for socket boxes + drilling and tapping heatsink

150+ hours

Using the PC software, load the data for the TUT (Tube under Test). Pinout and base connection information is taken from an extensive database of over 22,000 tube types.

Roetest … Read More »


HP Z3200 Belt Tensioner Repair

Photographic Printing, Tech. Comments Off on HP Z3200 Belt Tensioner Repair

22nd August

During a recent printing session, my Z3200 declared an “86:01 paper jam” error. Looking into the printer, I quickly realized that the carriage belt had gone slack. I replaced the OEM carriage belt a number of years ago with a very high-quality belt from LPS Computer, so I was quite sure the belt had not broken. A quick examination of the carriage belt path revealed that the belt tensioner had failed. More specifically, the shaft which holds the pulley had failed.

Belt Tensioner Pulley Failure

What to do? Obviously order a replacement part, but it would take several days to arrive, and my printer would be unavailable in the interim. So, I decided to repair the broken shaft. Past experience suggested that merely gluing the shaft back together would not work. I believe the shaft is ABS … Read More »


Apple IIe Power Supply Rebuild

Tech, Vintage Computers. Comments Off on Apple IIe Power Supply Rebuild

2nd September

The Apple IIe personal computer was manufactured from January 1983 through November 1993. I purchased an Apple IIe several years ago and put it into storage at the time. I recently pulled it out from storage and began the process of refurbishing it. Part of that process was rebuilding the power supply, which I will describe here.

The power supply appeared to be original to the computer with a date code of 47th week, 1985.

Apple II PCB Removed from case. Original capacitors in place. Build Date 47th week, 1985.

Examining the circuit board showed that the electrolytic capacitors were superior quality United Chemi-con.

Original Capacitors in place, output side.

By contrast, the line filter capacitor was a RIFA film capacitor of a type known to fail. Cracks were clearly visible in the outer case of the … Read More »


Tektronix TM500 Module Holder

3D Printing, Electronics, Restoration, Tech. Comments Off on Tektronix TM500 Module Holder

28th June

I have previously written about the substantial number of different modules available for the Tektronix TM500 and TM5000 module plug-in systems. Since the equipment is now anywhere from 20 – 40 years old it needs to be refreshed and/or repaired before going back into service. This often means working on the modules while they are not installed in the power frame:

TM500 Extender Overview: Connects between module and power frame.

TM500 Extender Overview: Connects between module and power frame.

Dan Meeks Extender Closeup. This extender allows monitoring of all supply voltages and currents. It also has LED indicators for each voltage rail.

Extender Plugged into Power Frame

Extender Plugged into module. This allows working on the module outside of the power frame.

From the image above, the extender board projects beyond the edges of the plug-in. This means that the plug in … Read More »


Tektronix TM500 Power Frame Tester

Electronics, Test Equipment. Comments Off on Tektronix TM500 Power Frame Tester

25th June

The Tektronix TM50n is an “n”bay (where n = 1 to 6, the number of bays) power frame which can host and power TM500 plug-ins. It was available in 1 through 6 bay versions and was the predecessor to the TM5000 power frame: See my post here about the TM5000 power frames. Tektronix themselves had dozens of plug-ins available which comprised power supplies, signal generators, oscilloscopes, multimeters, test oscillators, calibrators, attenuators, filters, logic analyzers, frequency counters, audio analyzers and more. It is important to note that while TM500 plug-ins can be used in the TM5000 power frame, the inverse is not true: TM5000 plug-ins cannot be used in a TM500 power frame.

Part of the repair/refresh process of any TM500 power frame requires the use of a Power Module Tester which (in conjunction with some basic test equipment … Read More »



Tektronix Type 106 Square Wave Generator Refresh

Electronics, Restoration, Tech, Test Equipment. Comments Off on Tektronix Type 106 Square Wave Generator Refresh

20th June

Introduced in 1966, the Tektronix 106 Square Wave Generator is a signal generator which can produce fast rise (<1nS @50 ohm loads positive or negative going) or high amplitude (120 Volts, high impedance load) square waves from 10Hz to 1MHz. It is used for oscilloscope calibration, risetime testing and for triggering extremely fast rise (<100pS) tunnel diode pulsers. The 106 uses a combination of vacuum tube and discrete solid-state technology. This is the sort of equipment that was used for development and testing during the NASA Apollo Program through the 1960’s.

The cost of the Tektronix Type 106 was USD 590 in 1966 or about USD 4900 in 2021 dollars. I was fortunate enough to obtain one of these units in decent condition and I was able to restore it to better than factory specification. What … Read More »


Tektronix TM5006 Power Frame Refresh

Electronics, Restoration, Tech, Test Equipment. Comments Off on Tektronix TM5006 Power Frame Refresh

17th June

The Tektronix TM5006 is a 6-Bay power frame which can host and power either TM5000 or TM500 plug-ins .

Tektronix themselves had about 130 different plug-ins available which comprised power supplies, signal generators, oscilloscopes, multimeters, test oscillators, calibrators, attenuators, filters, logic analyzers, frequency counters, audio analyzers and more. In addition, numerous third parties made plug-ins for the system. The total number of different plug-ins numbered at least 200. The system was introduced in 1972 and was available in some form through at least 1995. The system is remarkably interesting from a technology standpoint because it encompasses the move from discrete transistor circuitry in early equipment, evolving through microprocessor-controlled units in later equipment. The more modern TM5000 equipment also had network interface (GPIB) capability for control and data acquisition.

In terms of cost, a basic … Read More »


Tektronix Type 114 Pulse Generator Update

Electronics, Restoration, Test Equipment. Comments Off on Tektronix Type 114 Pulse Generator Update

16th June

This is an update to my previous post documenting my restoration/repair of two Tektronix Type 114 Pulse Generators. As of this writing I have completed some cosmetic work on the cabinets, front panels and carrying handles of both units. This includes cleaning and painting the cases, cleaning the front panels, knobs, BNC connectors and replacing the missing handle inserts.

Tektronix 114 Handle Insert Bottom Section Missing

Tektronix 114 Handle Insert New Aluminum Base Plates and OEM Example

Tektronix 114 Replacement Inserts and Tolex

Tektronix 114 Replacement Handle Insert and Tolex in place

Tektronix Type 114 Refinished Cabinet and Front Panel

Tektronix 114 Front Panel Cosmetics Completed

I have implemented a Maintenance and Inventory system which includes an equipment label with QR code. The code includes the Equipment Name, Serial Number, Instrument ID Number, and a summary of the latest service work completed on the unit. … Read More »


Racal 9478: Widespread Electrolytic Capacitor Failure

Electronics, Restoration, Troubleshooting. Comments Off on Racal 9478: Widespread Electrolytic Capacitor Failure

25th May

The Racal Dana Model 9478 Frequency Distribution System has an internal precision, oven-controlled crystal oscillator, or it can be phase locked to an external signal derived from a GPSDO or other master oscillator.  The system will automatically lock to an external signal above 100 mV, and with a standard frequency of 1, 5 or 10 MHz.  “In Lock” indication is provided.

I recently repaired two Racal 9478 units. What I found was widespread electrolytic capacitor failure such as I had never encountered before. A summary of the issues found in both units follows:

Virtually all electrolytic capacitors in both units (nearly 90 in all) had failed, showing either very low capacitance and/or very high ESR. Interestingly enough none showed short circuit failure.All the failed electrolytic capacitors were made by Philips in late 1980’s The -15v regulator was originally bolted … Read More »


Tektronix Type 114 Pulse Generator Repair

Electronics, Restoration, Tech, Test Equipment. Comments Off on Tektronix Type 114 Pulse Generator Repair

22nd May

I recently completed repairing/refreshing and calibrating two Tektronix Type 114 Pulse Generators. This is a solid state pulse generator with variable pulse width (100ns – 10ms) and period (1us to 100mS). It can produce pulses of both polarities (-10v to +10v into 50 ohms). It was introduced in 1965. The two examples I obtained were SN 001791 and SN 003460. Initally, both units were produced output, but the waveforms were distorted (rounded square waves) and far out of specification in terms of period, pulse width, and risetime.

Tektronix Type 114 SN 003460 Front Panel

Tektronix Type 114 SN 003460 Overview

Tektronix Type 114 Pulse Generator SN 001791 Front Panel

Visual inspection also revealed damaged components and mechanical damage. A summary of the issues found follows:

Pulse width and period were out of specificationNegative pulses and square waves were … Read More »



Cubic CDR-3250 Receiver Power Supply Refresh

Electronics, Premium Receivers, Radio. Comments Off on Cubic CDR-3250 Receiver Power Supply Refresh

9th January

The Cubic 3250 VLF-HF receiver is a 10kHz – 30 MHz DSP based radio receiver with 51 IF bandwidths and 7 receive modes. It falls into the category of professional/military grade equipment and the build quality certainly reflects this. According to Fred Osterman’s book, “Shortwave Receivers Past and Present, 3rd Ed.”, it was manufactured from the mid 1990s until at least 1998 (possibly later). I have found that the audio recovery and readability of this receiver is outstanding.

As both of my units were made in 1995/96, they are 25 years old and likely have thousands of hours of use. So I elected to replace all the electrolytic capacitors in the power supply with (arguably) an abundance of caution.


Cubic CDR-3250 Display Replacement

Electronics, Premium Receivers, Radio. Comments Off on Cubic CDR-3250 Display Replacement

9th January

The Cubic 3250 VLF-HF receiver is a 10kHz – 30 MHz DSP based radio receiver with 51 IF bandwidths and 7 receive modes. It falls into the category of professional/military grade equipment and the build quality certainly reflects this. According to Fred Osterman’s book, “Shortwave Receivers Past and Present, 3rd Ed.”, it was manufactured from the mid 1990s until at least 1998 (possibly later). I have found that the audio recovery and readability of this receiver is outstanding.

These receivers have a VFD (vacuum fluorescent display) as part of the front panel/human interface. The VFD in one of my units must have had many, many hours on it because it was quite fuzzy and dim, to the point of being blurry:

Aged, dim, blurry VFD

The old display on the CDR 3250 showed considerable burn in when viewed using … Read More »


HP 3245A Capacitor Replacement

Electronics, Restoration, Test Equipment. Comments Off on HP 3245A Capacitor Replacement

4th January

The HP3245A Universal Source (datasheet is copyright HP/Agilent) is a precision AC/DC voltage and current source that can provide a wide range of precise and repeatable voltages and currents up to +-100vdc and 100mA dc. It can also provide sine, square and arbitrary waveforms up to 1Mhz and 200vpp. Such an instrument is extremely useful in the lab for calibrating meters, driving current and voltage amplifiers and checking equipment. The particular units I have were built in 1992/1993 which means the electrolytic capacitors are approaching 30 years of age. I had decided to replace the RIFA line filter capacitors in (documented here) both my units and performed routine power rail voltage and ripple checking as part of that. For example:

+5.0840 4.4mv+15.194 30mV+18.625 29mV-18.691 28mV

The other power rails and HV Amp power supply also measured good, using an … Read More »


BK Precision 879B LCR Meter Repair

Electronics, Test Equipment. Comments Off on BK Precision 879B LCR Meter Repair

3rd January

The BK Precision 879B is a good quality, dual display 40,000 count LCR (inductance, capacitance, resistance) meter with 0.1% basic accuracy. It was first manufactured in 2010 and is still available (2021) for around $420 Cdn. I purchased mine several years ago and find it very convenient and easy to use.

BK Precision 879B

Things I like about the 879B:

Open/short calibration completes very quickly as opposed to the DE 5000Decent quality Kelvin clips and smd tweezers40,000 counts for extra accuracyVery good accuracy when compared to my HP4263ALong battery lifeEasy to use menu system and quick setup

A common problem with these units is the lack of robust input protection. What this means is that if you forget to discharge a sufficiently large capacitor and attempt to test it, you will damage the front end of the meter which will … Read More »


RIFA Safety Capacitor Replacement in HP Gear

Electronics, Restoration, Test Equipment. Comments Off on RIFA Safety Capacitor Replacement in HP Gear

3rd January

The post discusses the condition of RIFA Y Safety capacitors, which were prone to failure due to a cracked outer case. The issues were reportedly resolved after Kemet acquired RIFA in 2007. However, flawed capacitors remain in equipment older than 2007. The author has replaced many such capacitors in various older equipment, improving their safety and functionality.


Hickok 209A VTVM Restoration Part 7

Electronics, Restoration, Test Equipment. Comments Off on Hickok 209A VTVM Restoration Part 7

3rd January

I have completed the electrical restoration of one Hickok 209A VTVM. This included:

Replacing all the paper and electrolytic capacitorsReplacing all the carbon composition resistors (most were out of tolerance)Installing a polarized AC plug, line fuse and proper safety capacitorReplacing the meter movement (original was mechanically damaged)Rebuilding and restoring the battery holderBalancing the bridge tube resistorsGiving the unit a full check on all modes and ranges

With all of the above complete I can declare the unit ready to use. The cabinet still needs to be cleaned and refinished, but that will have to wait until warmer weather arrives and I can work outside.

The results of my testing were very interesting. I used my lab equipment (see below) to check the 209A on all of its ranges and modes (with the exception of the decibel range). … Read More »


Ebay IC Tester Instructions Update

Tech. Comments Off on Ebay IC Tester Instructions Update

14th November

Ebay IC Tester Instructions Update: Several years ago I posted the instruction and datasheets that came with the ubiquitous, generic Ebay IC Tester. These can be found here.

This post updates the original datasheet with new information: The datasheet with the tester indicates that 5v is the upper limit for zener diode testing, but recently tomtektest discovered that the unit can test zener diodes up to about 50v reliably. I dug into my parts bins and confirmed his finding using a range of zener diodes up to 48v. This is welcome information as it gives the tester additional usefulness in testing a much larger range of zener diodes.

Thanks for reading.

Shaun Merrigan


RIFA Safety Capacitor Failures

Electronics, Restoration, Test Equipment. Comments Off on RIFA Safety Capacitor Failures

13th November

RIFA Safety Capacitor Failures have been documented by many of us who restore and maintain vintage electronics equipment. One very spectacular failure was caught live here: courtesy Dave Jones of the EEVBLOG. These capacitors were widely used in test equipment manufactured during the late 1980’s through the 1990’s. The consensus is that the capacitors fail because the outer case (presumed to be a type of epoxy) develops cracks which allows moisture to penetrate the body of the capacitor. This leads to internal short circuits which cause the capacitor to fail catastrophically. Because these capacitors are line to ground, they could see line voltage whenever a piece of equipment is plugged in, even when switched off. The crack network can develop to the point where large pieces of the outer case spall off, exposing areas of … Read More »


Hickok 209A VTVM Restoration Part 6

Electronics, Restoration, Tech, Test Equipment. Comments Off on Hickok 209A VTVM Restoration Part 6

13th January

This is the sixth part of an “N” part series documenting my restoration of the Hickok 209A VTVM, SN 1333254.

Hickok 209A VTVM Restoration Part 6: Component replacement decisions

In this Part 6 of the series I will document the condition of the passive circuit components in the Hickok 209A VTVM, and justify why I decided to replace (or not replace) them.

Initial resistor and capacitor measurements Hickok 209A

Starting with the resistors, I measured 8 initially, and of those 5 were out of marked specification on the high side. One more was right at the high side specification and two were within specification. These were all 5% and 10% tolerance carbon composition resistors. Based on these data, I made the decision to replace all the 5% and 10% carbon composition resistors. I used 1% metal oxide resistors with … Read More »


Hickok 209A VTVM Restoration Part 5

Electronics, Restoration, Test Equipment. Comments Off on Hickok 209A VTVM Restoration Part 5

1st January

This the fifth part of an “N” part series documenting my restoration of the Hickok 209A VTVM, SN 1333254. Hickok 209A VTVM Restoration Part 5: Checking the meter movement.

This piece of test gear is all about the large, beautiful meter movement, so I need to determine if this one works properly. What I intend to do is connect the meter to a precision power supply and good ammeter through a current limiting resistor and then determine how the meter responds. The meter is supposed to be a 500uA full scale movement.

Here is the test setup:

Analog Meter Test Instrumentation Setup

A 10kohm limiting resistor is connected in series with the power supply. The power supply is a Tektronix PS5004 and the meter is a Tektronix DM5120.

Full Scale Deflection on the meter was about 497 uA:

Analog … Read More »


Hickok 209A VTVM Restoration Part 4

Electronics, Restoration, Test Equipment. Comments Off on Hickok 209A VTVM Restoration Part 4

1st January

This the fourth part of an “N” part series documenting my restoration of the Hickok 209A VTVM, SN 1333254. Hickok 209A VTVM Restoration Part 4: Restoring the battery holder.

In Part 3 of this series I documented the condition of the D Cell battery holder and outlined the restoration plan for the unit. The first step is to remove and restore the corroded battery holder.

Hickok 209A SN 133254 Corroded Battery Holder

Besides the obvious corrosion, the white connecting wire to the negative terminal was corroded under the insulation from the battery spring clip to the switch solder lug. I replaced the entire length of this wire. The other short wire and ring terminal were cleaned as described below.

Hickok 209A SN 133254 Corroded Terminal Wire

The process I used to restore the battery holder:

Desolder the two … Read More »


Hickok 209A VTVM Restoration Part 3

1st January

This the third part of an “N” part series documenting my restoration of the Hickok 209A VTVM, SN 1333254. Hickok 209A VTVM Restoration Part 3, corrosion issues and restoration plan.

As mentioned in Part 2 of this series, a visual inspection of the chassis of the 209A revealed a serious corrosion problem with the battery holder. The corrosion had migrated to the bottom of the case but not to the remaineder of the chassis. There were no batteries in the unit when I received it.

Hickok 209A SN 1333254 Battery Holder Corrosion

Hickok 209A SN 1333254 Battery Holder Corrosion

Hickok 209A SN 1333254 Battery Holder Corrosion

Hickok 209A SN 1333254 Battery Holder Corrosion

From the above images, it is clear that the battery holder will require some corrosion mitigation and restoration. Fortunately, it is restorable as the parts are … Read More »


Hickok 209A VTVM Restoration Part 2

1st January

This the second part of an “N” part series documenting my restoration of the Hickok 209A VTVM, SN 1333254. Hickok 209A VTVM Restoration Part 2, visual inspection.

Outside visual inspection results:

Overall good visual condition outsideMeter appears to move freely and does not stickMeter face is excellent and there are no scratches on the glassMeter bezel is dirty, but does not appear to be corrodedArea of corrosion noted at bottom of caseThe case has some minor paint scuffs and nicks accumulated over the past 60 yearsLine cord appears to be original and looks to be in good conditionHas an original rubber grommet where the line cord enters the caseNo obviously broken parts: lamp, pin sockets, dials are in good conditionHas DC Probe (reads 3.36 Mohms)No AC probe but does have the 4 wire AC probe connectorNo pin tip test … Read More »


Hickok 209A VTVM Restoration Part 1

Electronics, Test Equipment. Comments Off on Hickok 209A VTVM Restoration Part 1

31st December

This is the first installment in a multi-part series documenting my restoration of a classic Hickok 209A VTVM. First a description and some images:

This is a Vacuum Tube VoltMeter (VTVM) with a nominal 12 Mohm input impedance and one of the largest mechanical meter movements found on commerical/consumer equipment (viewing area about 8.5 inches diagonal). It was produced from about 1947 (earliest direct evidence) to at least 1961 (catalog reference). One of the units I have has 03-09-55 written in grease pencil on the back of the meter movement. The cost in 1947 was (reportedly) $133 USD which is about $1500 USD in late 2018. In comparison, the HP 410A (a lab grade instrument) sold for $245 USD in 1948 or about $2500 USD in late 2016 dollars. So the Hickok 209A was not aimed at the laboratory … Read More »


HP 1340A Display Repair -2

Electronics, Oscilloscopes, Test Equipment, Troubleshooting. Comments Off on HP 1340A Display Repair -2

29th December

HP 1340A Display Repair


HP 1340A Display Repair – 1

28th December

I purchased a couple of HP 1340A XYZ Displays which I thought would be useful as troubleshooting aids and as graphical displays of CRT technology (oscilloscope clocks, and the like). Upon receiving them, they both worked, but careful visual inspection showed some potentially serious problems. I will document the repair process here.

HP 1340A Overview

HP 1340A Overview

HP 1340A Overview

HP 1340A Overview

HP 1340A Overview

HP 1340A Rear Panel, High Serial Number

Visual inspection of the units revealed the following problems:

Heat damaged A1R81 (both units)Heat damaged A2R13 (both units)Loose mounting hardware and corroded wiring on A2Q2 (one unit)

Heat Damaged Components

LVPS A2Q2 Damage

Heat Damaged Components

A2Q2 is mounted directly to the case for heatsink purposes. The hardware was loose, therefore the transistor effectively had no heatsink. I suspect that it had been running hot for quite some time because the PVC insulation … Read More »


HP 3562A CRT Replacement

Electronics, Oscilloscopes, Test Equipment. Comments Off on HP 3562A CRT Replacement

28th December

Based on my own observations and reading, the CRT in the HP 3562A is a marvelous piece of engineering. However, it literally fatigues over time and at some point the deterioration cannot be compensated for by the range of adjustments. The solution is to replace the ageing CRT display with a modern LCD. It turns out that SimmConn Labs has such a kit:

http://www.simmconnlabs.com/1401/2501.html

Terry at D-Lab Electronics did a good video on how to replace the original CRT with the LCD Kit from NewScope:

https://youtu.be/WKz7GYBON7g

Terry does a great job of documenting the replacement process, so I will focus on the before/after results. I will start with original CRT images, followed by LCD images and by split screen comparison images. Since I also purchased the RGB to VGA adapter cable from SimmConn, I will conclude with an … Read More »


600 Ohm Terminator Build

Audio, Electronics, Test Equipment. Comments Off on 600 Ohm Terminator Build

27th December

When doing work on older audio gear it is sometimes necessary to maintain a 600 ohm impedance from, for example, a signal generator to a DUT or a piece of test gear. An easy way to do this is with a 600 ohm terminator. The article will document how I built such a terminator.

First I want to acknowledge the work of ElPaso TubeAmps (David Beard) who covered this very subject several years ago:

https://youtu.be/tIB3U-U29wg

50 ohm and 75 ohm BNC terminators are relatively easy to obtain, but 600 ohm terminators harder to come by. The solution is to build one as follows:

Obtain a suitable 50 or 75 ohm BNC terminator . You need the type which can be opened. One clue is that it may have flats on the end of the barrel which were used during assembly.The … Read More »


HP 3562A ROM Repair

Electronics, Test Equipment. Comments Off on HP 3562A ROM Repair

26th December

Early in 2018, I purchased an HP 3562A Dynamic Signal Analyzer for an excellent price on Ebay. The display looked great and it was physically in good condition. However, the unit failed the power on self test as follows:

HP 3562A Error Message on boot

This error code indicates a ROM IC failure.

HP3562A Diagnostic LED’s indicate Hex code 4 4 (0100 0100)

This code indicates a failure of ROM Chip U105:

HP 3562A Rev B ROM board. The problem ROM chip is the fifth chip down in first column (U105)

HP 3562A ROM Board Rev B

This ROM board is an older version using 32kx8 chips in two groups (Low Byte & High Byte) of 18 chips each. I had access to a second 3562A, and swapping ROM boards confirmed that the ROM board was the problem. Now I needed to:

Locate a suitable set … Read More »


AC Line Voltage 34 Hour Log

Electronics, Time and Frequency. Comments Off on AC Line Voltage 34 Hour Log

26th December

AC Line Voltage 34 Hour Log


iPad Not Charging After iOS 12.1 Update

Electronics, Tech. Comments Off on iPad Not Charging After iOS 12.1 Update

23rd December

I recently updated my iPad Air 2 to iOS 12.1 only to find that it would no longer charge via my computer’s USB 3.0 port. Specifically, I had been using, for many months, a decent quality aftermarket cable to connect/charge the iPad to my PC. There were no issues with charging or connectivity using the same configuration prior to the iOS 12.1 update.

A bit of digging suggested a two-part solution:

Power off and restart the iPadUse a genuine Apple cable

Well, powering off and restarting (using the same aftermarket cable) did not work; the iPad still would not charge. However either changing to a genuine Apple cable or a different aftermarket cable together with a power off and restart, did work. The iPad is now charging normally from the USB 3.0 port on my PC. … Read More »


Site Updated to HTTPS

Site Updates. Comments Off on Site Updated to HTTPS

22nd December

I have completed updating this site to use HTTPS. Enjoy!

Update: Having a few hiccups after updating to HTTPS. The public facing site became unreachable after a day or so, while the backend was working fine. GreenGeeks support suggested that my Cloudflare configuration was the culprit and recommended a couple of changes to the configuration.

It looks like this was the case, because the site is now reachable again after making the suggested tweaks to Cloudflare. Another issue arose with some pages not loading/working I had to manually edit the code to point to the correct https source which fixed that problem .

Also this prompted me to get rid of a fragment of Adobe Flash code that was still running on the site (a good thing) but served no useful purpose.

As EDI said: “It … Read More »


Weather Underground keeps Webcams

News, Site Updates, Weather. Comments Off on Weather Underground keeps Webcams

15th December

Weather Underground keeps Webcams

The Weather Underground PWS Network is a huge network of over 250,000 so called “backyard” or personal weather stations in North America and around the world.  From the Weather Underground PWS page:

“Weather Underground is a global community of people connecting data from environmental sensors like weather stations and air quality monitors so we can provide the rich, hyperlocal data you need to power your passions. The future of weather is personal, hyperlocal, and smarter than you think. Join our global community and contribute to the future of forecasting. 

Our network of sensors means more data. More data means better forecasts when it matters most. While everyone benefits from better data, sensor owners enjoy:

Precision: Get weather conditions for your exact location (not your neighbor’s or at the airport)
Visualization: See comprehensive dashboards and graphs of your station data
Historical: Archive your … Read More »


Ebay IC Tester Instructions

Electronics, Tech. Comments Off on Ebay IC Tester Instructions

2nd December

Ebay IC Tester Instructions

The ubiquitous IC/Component tester found on Ebay usually comes without any instructions or documentation:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The unit I purchased came with a one page, 2-sided photocopy instruction sheet, so I thought I would share it here:

 

 

As far as I can tell, this unit will identify and test the following:

Common linear and logic IC’s
Some transistors; seems to be limited to bipolar
Zener Diodes

It does not appear to identify:

LED’s
JFET’s
Three terminal regulators

 

Thanks for reading,

 

Shaun M


Tektronix CG5001/CG5011 Pulse Rise Time Measurement

Electronics, Oscilloscopes, Test Equipment. Comments Off on Tektronix CG5001/CG5011 Pulse Rise Time Measurement

25th September

Tektronix CG5001/CG5011 Pulse Rise Time Measurement

I wanted to measure the rise time of the normal and fast edge pulses in a new acquired Tektronix CG5011 calibration generator.  The equipment line is as follows:

Tektronix TM5006 mainframe

Tektronix CG5011 Calibration Generator

Tektronix CG5001 Calibration Generator

Tektronix/Tegam 015-0611-01 Pulse Head

HP 83480A Communications Analyzer

HP 83483A Electrical Sampling Module (20GHz)

Background:  The original 015-0311-00/01 pulse head was used in combination with the CG551AP and CG5001 calibration generators. The 015-0611-00/01 pulse head is the later version  used on the CG5010 and CG5011 calibration generators.   The primary differences between the later 0611 and earlier 0311 are:

The 0611 has faster edge rise time of <150 ps or < 160 ps for the Tegam version
The 0311 has slower edge rise time  of <200 ps
The 0611 is larger (taller) than the 0311
The 0611 made by Tegam has an SMA output connector
The 611 made by … Read More »


Tektronix 7904A S52 Pulse Response

Electronics, Oscilloscopes, Test Equipment. Comments Off on Tektronix 7904A S52 Pulse Response

20th August

Tektronix 7904A S52 Pulse Response

This post documents my investigations into the following vintage electronic gear:

Tektronix 7904A Mainframe (500 MHz Bandwidth)
Tektronix S52 Pulse Head (tr<25ps)
Tektronix S4 Sampling Head (tr < 25ps)
Tektronix 7S12 TDR/Sampler Plug-in

Here is the test setup:

Tektronix 7904A using 7S12 with S52 and S4 heads. 34ps system rise time. She’s working Captain (MS)

 


HP 8903B Audio Analyzer PCB Pad Replacement

Electronics, Test Equipment. Comments Off on HP 8903B Audio Analyzer PCB Pad Replacement

18th August

HP 8903B Audio Analyzer PCB Pad Replacement

Visual inspection of my recently acquired HP 8903B Audio Analyzer revealed that the polymer pads on the bottom side of the main PCB were seriously deteriorated:

 

HP 8903B Deteriorated Pads Overview

 

HP 8903B Deteriorated Pads Closeup

 

HP8903B Deteriorated Pad Macro Lifted

Besides making an unsightly mess, this residue may form corrosive products which, over time, could damage the PCB.  Also, the pads no longer perform their bottom cover to PCB isolation function.  So all the old pads and residue had to be removed and new pads installed.  Lintless wipes, isopropyl alcohol, and nitrile gloves were the chosen tools.

 

HP 8903B partly cleaned PCB

 

HP8903B Board Cleaned and Pads Replaced Overview

 

HP8903B Board Cleaned and Pads Replaced Macro

The residue cleaned up completely, and new pads were installed. I won’t need to … Read More »


Tektronix 7854 Waveform Keyboard Rebuild

Electronics, Oscilloscopes, Tech. Comments Off on Tektronix 7854 Waveform Keyboard Rebuild

15th August

Tektronix 7854 Waveform Keyboard Rebuild

From the Tek Wiki:

The Tektronix 7854 Waveform Processing Oscilloscope, introduced in 1980, is a 400 MHz combined analog / digital mainframe in the 7000 series that takes two vertical and two horizontal 7000-series plug-ins. In addition to a conventional analog (real time) scope, it contains an equivalent-time sampling 10-bit digitizer and a programmable waveform processor with GPIB interface. The waveform processor can be programmed using a detachable calculator-style keyboard, using postfix operators (“reverse Polish notation” like HP calculators) that operate on entire waveforms, not just individual numbers.

Tek 7854 Mainframe #2 after cleaning

Tek 7854 Mainframe after cleaning

 

It is to the repair of the detachable keyboard that this post is devoted.  I purchased a keyboard for a reasonable price only to find that some keys were intermittent, and some did not work at all.

Opening up the keyboard showed … Read More »


The uTracer Tube Tester and Curve Tracer

Electronics, Vacuum Tubes. Comments Off on The uTracer Tube Tester and Curve Tracer

14th August

The uTracer Tube Tester and Curve Tracer

I have completed building my uTracer (micro Tracer) computer based vacuum tube tester and curve tracer.  This unit, designed by Ronald Dekker described on his website:

The uTracer is much more than a simple tube tester; it is also a curve-tracer. It measures both the anode as well as the screen currents for a range of specified bias conditions, and arranges the measurements in meaningful sets of curves. From these curves parameters like the transconductance or the output resistance can then be extracted and plotted as a function of bias. Alternatively the uTracer can be used as a tester which extracts important parameters like Ia, Rp, gm and um in your favorite bias point in a matter of seconds. http://dos4ever.com/uTracer3/uTracer3_pag0.html

Ronald Dekker makes this tester available as a kit, with detailed assembly and testing instructions.  One of … Read More »


Tektronix DSA602A Digitizing Signal Analyzer

Electronics, Oscilloscopes. Comments Off on Tektronix DSA602A Digitizing Signal Analyzer

14th August

Tektronix DSA602A Digitizing Signal Analyzer Part 1

I recently had the opportunity to purchase one of these units, and I am thoroughly enjoying the process of  checking its operation and getting to know how to use it.  This unit is a laboratory grade, very accurate digitizing oscilloscope from about 1990.  From the Tek Wiki entry:

Inputs
3 amplifier bays, up to 12 channels (using 11A34 plug-ins)

Resolution
8 bits; averaging of N acquisitions increases by log2(N) up to 14 bits

Display resolution
50 pixels/Div

Sample rate
DSA601, max 1 GS/s; DSA602, max 2 GS/s (one channel, left plugin)

Record length
512 to 32768 samples

Sweep rate
50 ps/Div  to 100 s/Div

ENOB
7.2 bit up to 10 MHz, 6.3 bit @ 250 MHz, 5.7 bit @ 500 MHz, 4.5 bit @ 1 GHz

Screen
magnetic deflection color computer monitor, 10″ diagonal (130 mm × 168 mm), 552×704 pixels, 22×11 infrared touch-screen grid

Power
90-132 V or 180-250 V, 48-72 Hz, 465 W (DSA601A) / 585 W (DSA602A)

Features

Automated signal measurements (rise, fall, period, frequency, width, delay, phase, duty … Read More »


Tektronix Scope-Mobile Cart Repair Part 3

Electronics, Oscilloscopes. Comments Off on Tektronix Scope-Mobile Cart Repair Part 3

7th May

Tektronix Scope-Mobile Cart Repair Part 3

 

Part 1

Part 2 

This is the conclusion to my repair of a Tektronix 202-2 Scope-Mobile Cart.  Recall that the problem was three fractured trunnion mount bosses which rendered the cart useless (and unsafe) under load.  My proposed solution was to place the bosses into compression by putting a 6mm countersunk bolt through the trunnion mount concentric with the existing hole in the boss.  By using appropriate sized washers between the top of the boss and the frame member I ensure that the boss is placed into compression and the frame member is securely clamped.  This avoids the tensile loading which fractured the bosses initially.

 

Trunnion to member closeup with new bolt and washers in place

The holes in the trunnion mount were countersunk to fit the flat head socket bolts:

Countersunk Hole for new bolt

 

Read More »


Ring Video Doorbell Cold Weather Charging

Ring Doorbell, Tech. Comments Off on Ring Video Doorbell Cold Weather Charging

24th February

Ring Video Doorbell Cold Weather Charging

This is a follow-up to an earlier post I made concerning the cold weather performance of the original Ring Video Doorbell. I have had the opportunity to observe the behavior of both the original Ring (i.e., the non “Pro”) and the Pro versions through several cycles of very cold (down to -30C) weather over the past two years, and I can now draw some conclusions.

Background information:

I have both the original Ring and the Ring Pro
The original Ring is hardwired to my mechanical chime doorbell
The Ring Pro is hardwired to my mechanical chime doorbell
The voltage at each doorbell is in the 19-20 VAC range (Klein CL1000 portable DVM)

Conclusions:

The Ring Pro doorbell seems unaffected by external temperature.  It operates properly even through prolonged stretches (10 days or more) of -20C to -30C outdoor temperatures.

The original Ring doorbell … Read More »


Tektronix 556 Dual Beam Oscilloscope Testing: Vertical Bandwidth

Electronics, Oscilloscopes, Tektronix 556. Comments Off on Tektronix 556 Dual Beam Oscilloscope Testing: Vertical Bandwidth

27th January

Tektronix 556 Dual Beam Oscilloscope Testing: Vertical Bandwidth

I have been doing some basic testing of my Tektronix 556 Dual Beam Oscilloscope, and I have documented some parts of this process.  I have also captured images of the traces, which I will share here.

Test Setup: Tektronix 556, 1A2 plug-in, Timebase A, Tektronix SG 503 Generator, and Tektronix TG 501 Time Mark Generator

I found the -3db vertical bandwidth of the 1a2/556 to be 65 Mhz, which is to be expected for the 50 Mhz rated 1A2.

TM 500 Module with Plug ins

TM 500 Module

50 kHz Reference Signal 6v peak to peak

Tek 556 with 1A2 Vertical 50 KHz BW Test

5 MHz Sine Wave 6v peak to peak

Tek 556 with 1A2 Vertical 5 MHz BW Test

20 MHz Sine Wave 6v peak to peak

Tek 556 with 1A2 Vertical 20 … Read More »


Tektronix 556 Fan Motor Repair Part 2

Electronics, Oscilloscopes, Tektronix 556. Comments Off on Tektronix 556 Fan Motor Repair Part 2

22nd January

Tektronix 556 Fan Motor Repair Part 2

In this continuation of Tektronix 556 Fan Motor Repair Part 1, I have removed the motor and mount assembly and disassembled it.  Now I need to figure out the problem and rebuild the motor.

Tektronix 556 Fan Motor Overview, mounted in place

556 Fan Motor Rear

Tektronix 556 Fan Motor removed from mounts.  The Tektronix part number is 147-0029-00.

 

Tektronix 556 Fan Motor

Tektronix 556 Fan Motor removed from mounts.

Tektronix 556 Fan Motor

Tektronix 556 Fan Motor removed from mounts.

Tektronix 556 Fan Motor

The next few images show the disassembled parts of the motor:

Rotor, end bells and bushing assembly

556 Bushing Assemblies and Rotor

End bell inside, retainer, spring washer felt and bushing.

556 Fan Motor Bushing Assembly

End bell and bushing assembly

556 Bushing Assembly

Rotor and spacers

556 Fan Motor Shaft … Read More »


Tektronix 556 Fan Motor Repair Part 1

Electronics, Oscilloscopes, Tektronix 556, Vacuum Tubes. Comments Off on Tektronix 556 Fan Motor Repair Part 1

19th January

Tektronix 556 Fan Motor Repair Part 1

I was recently fortunate enough to acquire a Tektronix 556 Dual Beam Oscilloscope with many accessories and in good condition.  Unfortunately, the cooling fan on the scope was very loud and more concerning, it emitted an alarming metal on metal contact sound.  After verifying basic operation of the oscilloscope, I decided to repair the cooling fan.  This process is documented in the images and commentary that follow.

Part 1: Removing the Noisy Fan Motor

556 Cooling Module with filter and mesh screen removed.  The fan is connected to the chassis wiring at the ceramic terminal which is circled:

556 Fan Cooling Module Outside

Fan to chassis wiring connection terminal.

 

556 Fan Cooling Module Fan Connections

Inside of cooling module and bottom side of motor (fan blade removed):

556 Fan Motor Underside

Back side of motor (fan blade … Read More »


Tektronix Scope-Mobile Cart Repair Part 2

Electronics, Oscilloscopes, Tech. Comments Off on Tektronix Scope-Mobile Cart Repair Part 2

7th January

Tektronix Scope-Mobile Cart Repair Part 2

This post continues my repair of the Tektronix Scope-Mobile Cart and  trunnion mounts. Here is Part 1, which details the problem and my proposed solution.

The original design used 5/16″ button head bolts which screwed into the bosses and attached the aluminum box frame member to the polymer trunnion mount:

Trunnion to member overview-1

Trunnion to member closeup-2

Trunnion to member closeup with original fastener-3

Trunnion to member closeup with original fastener and cover in position-4

It is obvious that overtightening these bolts put the bosses into tension which caused them to fail.  The gap between the member and the boss “spring loads” the system and puts additional tensile stress on the boss.  While an aluminum casting could easily handle these stresses, the polymer obviously could not.

What I did was to glue the fractured bosses into … Read More »


Tektronix Scope-Mobile Cart Repair Part 1

Electronics, Oscilloscopes. Comments Off on Tektronix Scope-Mobile Cart Repair Part 1

6th January

Tektronix Scope-Mobile Cart Repair Part 1

I was lucky enough to obtain a Tektronix 202-2 Scope-Mobile Cart.

Tektronix 202-2 Scope-Mobile scanned overview image

 

Upon examining it, I found that the scope tray was loose and the tilt mechanism did not function properly.  The cause for this was broken trunnion mounts on both sides of the cart as follows:

Tektronix 202-2 Mobile Cart Chassis Parts

 

Trunnion Mount and Broken Bosses Overview

 

Trunnion Mount and Broken Bosses Overview

Three of the four bosses were fractured with the fracture surface indicating tensile overload.  I suspect that the bolts were overtightened and the bosses fractured. Overtightening loaded the bosses in tension by trying to compress the box frame member.  Unfortunately this type of polymer (some type of hard thermoplastic) is not good in tension.

Other mobile carts I have seen use cast aluminum for … Read More »


New Vacuum Tube Box Scans

Electronics, Vacuum Tubes. Comments Off on New Vacuum Tube Box Scans

6th January

New Vacuum  Tube Box Scans

I have uploaded several new vacuum tube box scans including Philco, Canadian General Electric, Wards, and Hitachi (Hit-Ray):

 

Wards Tube Box_3

Wards Tube Box_2

Wards Tube Box_1

Philco Tube Box_4

Philco Tube Box_3

Philco Tube Box_2

Philco Tube Box_1

Motorola Small Tube Box_4

Motorola Small Tube Box_3

Motorola Small Tube Box_2

Motorola Small Tube Box_1

Lafayette Tube Box_4

Lafayette Tube Box_3

Lafayette Tube Box_2

Lafayette Tube Box_1

Hitachi Tube Box_4

Hitachi Tube Box_3

Hitachi Tube Box_2

Hitachi Tube Box_1

CGE Radiotron Tube Box_2 (4)

CGE Radiotron Tube Box_2 (3)

CGE Radiotron Tube Box_2 (2)

CGE Radiotron Tube Box_2 (1)

Wards Tube Box_4

 

Thanks,

 

Shaun M.


Tektronix 556 Dual Beam Oscilloscope Images

Electronics, Oscilloscopes, Tektronix 556, Vacuum Tubes. Comments Off on Tektronix 556 Dual Beam Oscilloscope Images

31st December

Tektronix 556 Dual Beam Oscilloscope Images

What follows is a series of images of my Tektronix 556 Dual Beam Oscilloscope displaying various waveforms.  I am learning about this scope and how to use it.

A brief description of the unit can be found here: Tektronix 556

Tektronix 556 Oscilloscope: Square Waves, one channel per beam.

Tektronix 556 Oscilloscope: Pyramid waves, two channels per beam

Tektronix 556 Oscilloscope:Pyramid waves, two channels per beam

Tektronix 556 Oscilloscope:Pyramid waves, one channel per beam

Tektronix 556 Oscilloscope: Two channels per beam, no inputs grounded.

 

Thanks for reading.

 

Shaun M.



Tektronix 556 Dual Beam Oscilloscope

Electronics, Oscilloscopes, Tektronix 556. Comments Off on Tektronix 556 Dual Beam Oscilloscope

5th December

Tektronix 556 Dual Beam Oscilloscope

I had recently the unique opportunity to acquire a complete Tektronix 556 Oscilloscope setup.  This comprised the oscilloscope itself, the matching scope cart, original manual, probes and 12 plug-in units.  This in itself is rare enough, but in addition, this particular scope has the optically desirable blue phosphor CRT and Tektronix C-27 Camera Bezel.   This 50 MHz bandwidth oscilloscope was the state of the art when it was introduced in the mid 1960’s: Tekwiki Tek 556

This will be the first of many posts and updates as I work my way through checking and restoring this beautiful scope.

And now some images:

Tektronix 556 Oscilloscope

Tektronix 556 Oscilloscope

Tektronix 556 Oscilloscope

Tektronix 556 Oscilloscope

Tektronix 556 Oscilloscope

Thanks!

 

Shaun Merrigan

 

 


Tektronix Oscilloscopes 7904, 2467B, 2465B at 1GHz

Electronics, Oscilloscopes. Comments Off on Tektronix Oscilloscopes 7904, 2467B, 2465B at 1GHz

30th October

Tektronix Oscilloscopes 7904, 2467B, 2465B at 1GHz

The images to follow show a 1 GHz sine wave (amplitude not changed during the testing) on the following Tektronix oscilloscopes:

Tektronix 7904 with 7A24 vertical (400 MHz) and 7B92A horizontal

Tektronix 2467B (400 MHz scope)

Tektronix 2465B (400 MHz scope)

 

1 GHz Sine wave input on a Tektronix 7904 with a 7A24 vertical module

 

500 MHz Sine wave input on a Tektronix 2467B

 

1 GHz Sine wave input on a Tektronix 2467B

 

1 GHz Sine wave input on a Tektronix 2465B

 

1 GHz Sine wave input on a Tektronix 2465B

I have checked the bandwidth of the both the 2465B and 2467B used here, and they meet the 400MHz requirement at -3db (using a Tektronix SG504 with leveling head).  The bandwidth of the 7904 mainframe + 7A24 vertical plug-in used in this … Read More »


Tektronix 7904 Oscilloscope

Electronics, Oscilloscopes. Comments Off on Tektronix 7904 Oscilloscope

30th October

Tektronix 7904 Oscilloscope

Here are some images of one 7904 mainframe  with a 7A24 vertical module and a 7B92A horizontal module.  The scope screen shows the pulse from an S52 pulse head; the rise time is about 850ps which translates into a bandwidth of about 412 MHz.  Since the 7A24 plug-in is specified at 400 MHz, this is about right.

 

Very fast rise time pulse on a Tektronix 7904 with a 7A24 vertical module

 

This is the same pulse from an S52 pulse head but using an S4 sampling head instead of the 7A24 vertical amplifier

Very fast rise time pulse on a Tektronix 7904 with an S4 sampling head

 

Shaun Merrigan


Tektronix 7000 Series Equipment

Electronics, Oscilloscopes, Time and Frequency. Comments Off on Tektronix 7000 Series Equipment

25th October

Tektronix 7000 Series Equipment

I am doing some testing on recently acquired Tektronix 7000 series equipment.  Involved in these images is a Tektronix 7904A mainframe using a 7S12 TDR/Sampler plug in with an S52 pulse generator and S4 sampling head.

Tektronix 7904A Fast Rise Time Pulse

Tektronix 7904A Fast Rise Time Pulse

The rise time on of the pulse is about 32ps which translates to a bandwidth of about 11 GHz; all this for a few hundred dollars.

Shaun Merrigan


Fallout 4 Vacuum tubes and Nixie tubes

Gaming, Nixie Tubes, Tech, Vacuum Tubes. Comments Off on Fallout 4 Vacuum tubes and Nixie tubes

8th February

Fallout 4 Vacuum tubes and Nixie tubes

I have been working my way through Fallout 4 and during my explorations I noticed that the labs and military installations are loaded with vintage vacuum tube equipment.  I thought I recognized the front panel of at least one piece of gear:

Front Panel render from Fallout 4 (Bethesda Softworks):

Fallout 4 Front Panel

 

 Now compare this image with the front panel of the Racal RA-17:

Racal RA17 Front Panel

The resemblance of the Fallout 4 render to the real Racal RA17 is striking.  This Racal-like front panel appears in nearly every lab and/or military installation that I have explored.

Another rack of equipment very frequently seen in labs and military installations is this one:

 

Fallout 4 Equipment Rack (Bethesda Softworks

Fallout 4 equipment rack

This image clearly shows:

A nixie tube … Read More »


NEST Thermostat Network Isolation

NEST Thermostat, Ring Doorbell, Tech. Comments Off on NEST Thermostat Network Isolation

6th February

NEST Thermostat Network Isolation

With the proliferation of IoT (Internet of Things) objects such as smart thermostats, sensors of all kings, video cameras, video doorbells, light bulbs, media hubs and the like it comes as no surprise that security problems are cropping up.  These IoT devices are proving to be a door through which malicious software can gain direct access to your home network behind your router.  An excellent summary of the potential security problems with IoT devices can be found here InfoSec Resources Iot Security Summary.   The takeaway is that these devices are vulnerable, and attackers can use them to penetrate your home network.  Once an attacker gains access to the network behind your router, they have the “keys to the kingdom”.  What is the solution?  As usual with home network security, there are several solutions ranging from relatively … Read More »


Ring Video Doorbell Cold Weather Charging Problem and Solution

Ring Doorbell, Tech. Comments Off on Ring Video Doorbell Cold Weather Charging Problem and Solution

23rd January

Ring Video Doorbell Cold Weather Charging Problem and Solution

I installed a Ring Video Doorbell (RVD) last spring (2015) and overall, I am quite happy with the utility and performance of the unit. Like any new IoT (Internet of Things) device there will be issues, growing pains and problems to be solved.  This post concerns the cold weather performance of the Ring Video Doorbell.

There are several relevant background points:

The Ring Video Doorbell is installed hardwired
The Ring Video Doorbell charges from the wiring above about -19C (-2F)
The Ring Video Doorbell is installed in a single family residence with the camera facing the street
The Ring Video Doorbell wireless signal has to penetrate wire mesh stucco and several walls to get to my router

Initially, I had my RVD motion settings to maximum sensitivity (30 ft radius) and “Standard” Alert frequency.  This meant I was … Read More »


Numitron Clock Project

Tech, Time and Frequency, Vacuum Tubes. Comments Off on Numitron Clock Project

21st February

Numitron Clock Project

Numitrons are low voltage incandescent display devices perfected and marketed by RCA (see RCA advert above) in the early 1970’s.  I would call this a bridge technology as the display is incandescent, but can be driven by integrated circuits.   They were quickly displaced by solid state LED (light emitting diode) devices from the mid 1970’s onward.

This is a Numitron:

RCA Numitron Advert

The look and feel of a Numitron display appeals to me and I wanted to reboot my building and soldering skills , so I decided to build a Numitron clock.  I based my clock on the RCA DR2000 which has a beautiful 15mm display height and a board and parts kit (no longer available) from Richard White.  Here are some images of the construction process:

  

And here is an image series of the finished clock … Read More »


Sonos: Music library not found fix

Tech. Comments Off on Sonos: Music library not found fix

2nd January

Sonos: Music library not found fix

I have a wired Sonos system and a central media server (WHS 2011) which hosts all my media content .  Prior to  the latest Sonos update (v5.2), I had no problems accessing my music which is hosted on the server via any connected Sonos controller on either PC’s or iPads.  Post v5.2, however I lost access to the music library.  I tried:

Deleting the shared music folder and re-adding it from different controllers
Modifying the shared music folder permissions on the server
Confirming that SONOS was added as a user on the server
Installing the Sonos controller on the server (!!) and adding the shared directly from the server

All of the above attempts failed with the same error:  The computer “server123” cannot be found.  What is important here is that all my other music sharing services (iTunes, Windows Media Player, … Read More »


HP/Symmetricom Z3805A GPS Disciplined Oscillator

Tech, Time and Frequency. Comments Off on HP/Symmetricom Z3805A GPS Disciplined Oscillator

22nd November

I recently acquired two HP/Symmetricom Z3805A GPS Disciplined Oscillator receiver/clocks.  These units seem to have several different configurations both inside the box and of the box itself, but all appear to have:

Two 10Mhz outputs
Two 1PPS outputs
24v DC power requirement

Inside the box, I have seen reports of:

HP 10811 DOXCO (10Mhz)
Symmetricom  DOXCO (5Mhz with a doubler)
MTI 260 DOXCO
16 channel GPS receiver (newer builds)
6 channel GPS receiver (older builds)

The box itself can be Samsung rack mount or HP benchtop.   My particular units were older  Samsung rackmount builds, but do have the desirable HP 10811 DOXCO.   Both units had older 6 channel GPS receivers that exhibited the 1024 week GPS rollover bug.  (That is, they displayed a date that was 1024 weeks in the past due to nature of the 10 bit week counter used in the receiver.)  I simply swapped the GPS … Read More »


Lucent KS-24361 HP/Symmetricom Z3809A, Z3810A, Z3811A, Z3812A GPSDO system

Tech, Time and Frequency. Comments Off on Lucent KS-24361 HP/Symmetricom Z3809A, Z3810A, Z3811A, Z3812A GPSDO system

9th November

Lucent KS-24361 HP/Symmetricom Z3809A, Z3810A, Z3811A, Z3812A GPSDO system

I have updated my Time and Frequency GPSCon pages to show my recently powered on Lucent KS-24361 HP/Symmetricom Z3809A, Z3810A, Z3811A, Z3812A GPSDO system.

The GPSCon page can be found here: Lucent GPS

Here is a photo of the unit:

In a nutshell, these two units each contain a Double Oven Controlled Quartz Crystal Oscillator (DOCXO) made by Milliren (MTI).  Both of these oscillators are GPS disciplined using an onboard GPS timing receiver located in the REF 1 box. 

These are NOS (new old stock) surplus units which were manufactured around 2000.  The useful outputs are 10 and 15Mhz and 1PPS.  It will be very interesting to see how this unit performs over the long term.

 

Shaun Merrigan


Nest connectivity and charging problems solved

NEST Thermostat. Comments Off on Nest connectivity and charging problems solved

9th November

Nest connectivity and charging problems solved:

I have two NEST thermostats; one first generation and one second generation.  I experienced intermittent connectivity issues with my gen1 Nest soon after I installed it.  Initially I determined that it was not charging properly so I brought out the “C” (AC Common) wire from my furnace control board to the NEST and the charging problem was solved.  When I  installed the gen2 NEST, I made sure the “C” wire was available at installation.  I have no charging problems with either NEST now.

 

Connectivity problems would come and go, sometimes going many weeks or months between incidents.  I tried many solutions (port forwarding .lease times, static ip, etc) with varying degrees of success.  The connectivity problems were irritating rather than debilitating; most of the time the NEST worked fine.  The same pattern occurred after I installed … Read More »


NEST Connectivity Issues Solved

NEST Thermostat, Tech. Comments Off on NEST Connectivity Issues Solved

12th October

I have two NEST thermostats, one v1 and one v2. The v1 had been ticking along fine until about July 2014 when I began to experience connectivity problems. More specifically, the thermostat itself would say that it was connected properly,  but the NEST browser and mobile apps would show it as offline. I tried all the usual fixes: reboot, restart, reset, both (router and NEST), static ip, DHCP Leasetime tweaks, etc.  Long story short, nothing I did solved the connectivity issues.

As it turned out, I was reconfiguring my home network and decided to change my main router from a Netgear WNDR4500 to an ASUS RT-AC68U. This change has resolved all my NEST connectivity issues. NEST Connectivity Issues Solved !  Both my NEST thermostats are fully connected and accessible any time I check them. It turns out that the RT-AC68U has … Read More »


Dell Poweredge CS24-SC Servers

12th October

I recently acquired two Dell Poweredge CS24-SC Servers, each equipped with dual Xeon 5420 processors and 8GB of ECC ram. I love this industrial grade gear because:

1) the excellent quality of construction
2) ease of servicing and use
3) designed to run 24/7 for years
4) no frills, but good solid, reliable hardware
5) Baseboard (BMC) management features
5) amazingly power frugal with the right settings

These servers were (reportedly) part of a large run of 10,000 or more units manufactured for cloud/cluster computing. Many of them have turned up in the surplus market over the past few years. The units I obtained had sequential serial numbers and were configured identically. They were very clean and in excellent condition. The BMC firmware was the latest available version, and the motherboard firmware was the penultimate version. I therefore chose not to attempt any firmware upgrades.

I installed Linux … Read More »


Landscape Photo Diary Updated

News, Site Updates. Comments Off on Landscape Photo Diary Updated

30th June

Landscape Photo Diary Updated

I recently had the opportunity to photograph the area around Drumheller, Alberta.  This is a spectacular and beautiful area of Alberta. I took time to walk and drive parts of the now abandoned CN Drumheller Subdivision (CN Rail).  This particular subdivision winds its way through some wonderful areas of the Alberta Badlands.

I have put up a selection of my landscape and railway images on my photo website:  Drumheller Badlands, Spring 2014

 

Enjoy the wonderful Alberta Summer!

 

Shaun M


Nest thermostat: Should I assign an IP or Not?

NEST Thermostat, News, Tech. Comments Off on Nest thermostat: Should I assign an IP or Not?

25th June

Nest thermostat: Should I assign an IP or Not?

The question is: Does assigning the NEST thermostat a static IP using your router result in a more reliable wireless connection?  For my first generation NEST running v4.2.3 of the NEST software, the answer is a definite no.

Background:

I am using my home router as a DHCP  server in order to assign IP addresses to various devices behind it.  This is the typical default behavior of most home routers.  I like to tweak the setup, however and assign static IP addresses to various devices so that troubleshooting is simplified and  IP address conflicts are avoided.

My NEST thermostat connectivity had been generally very good, until a couple of weeks ago when I found that the NEST thermostat could not connect reliably to my router.  (I had updated my router firmware about that time as … Read More »


Xbox 360 Power Supply Replacement

Gaming, News, Tech. Comments Off on Xbox 360 Power Supply Replacement

17th January

Xbox 360 Power Supply Replacement

If you own one or more Xbox 360 in its various incarnations, including the newer 360S and 360E, you have likely experienced a power supply failure. These units all use an outboard power supply which plugs into the wall outlet at your local voltage, and connects to the 360 by a special power cable. I say special cable because the cable and plug design has charged numerous times over the years. The failure modes that I have experienced go something like this:

1) The power supply (“brick”) begins to get noisy on power up, but then settles down to its former noise level in a few minutes. This behavior continues for a few weeks or months. At this point I generally take the brick outside and blow it out with a super duster (canned air).
2) The noise … Read More »


Xbox One Media Center Solution

News, Tech. Comments Off on Xbox One Media Center Solution

24th December

Xbox One Media Center Solution

I have been learning the ins and outs of my new Xbox One over the past couple of weeks and here are some of my observations:

I like the tiled menu interface, and the look and feel of the menus
The entire system feels very fast and responsive
The integration of kinect seems to work well
No TV integration (guide or satellite/cable box) in Canada
Some games available, but nothing I am interested in as yet; let’s see what happens at E3
No Media Center (like the Xbox 360)

The last point is really critical for me.  I want to use my Xbox One for my own music, pictures, videos, recorded TV, etc.  In other words, I want Media Center functionality on my Xbox One.  This is right in line with Microsoft’s vision for the Xbox One :

“The all-in-one entertainment system. Where … Read More »


NEST Thermostat Update and Voltage Measurements

18th November

NEST Thermostat Update and Voltage Measurements

I have had my NEST Gen1 for almost 16 months now and I probably could not go back to a regular dumb thermostat, given the choice.  The NEST charging problem has been solved by connecting the “C” (AC Common) wire from my furnace to the NEST.  See this post for details: Nest Thermostat Charging Solution

I find the monthly NEST Energy Reports very useful, and I am saving them so that when I make important changes to our house (new windows, more insulation, more efficient furnace, etc) I can see an actual difference.

 

I thought it would be helpful to anyone still troubled by the charging problem if I posted my NEST reported and measured voltages:

Furnace running (heating) NEST Reported Voltages: Voc 38.33V, Vin 31.57V, Vbat 3.864V, Lin 100mA (i)

Voltage measured between Rc and C (Power and … Read More »


The Nike FuelBand: 5 Months On

News, Tech. Comments Off on The Nike FuelBand: 5 Months On

15th November

The Nike Fuel Band: 5 Months On

I purchased a Nike Fuel Band in late June 2013 with an idea that I could use it as a step counter over the summer and during the winter.  I did quite a bit of research, and examined competing products. While other products had more features, the Nike FuelBand was elegantly simple, easy to use, looked great and had the best software support (I do not use Android devices).  Since receiving it in June, I have used it continuously for over 5 months, and I am still using it.  How do I feel about it?  I love it.  It is easy to wear, rugged, and easy to use.   No gimmicks, no BS; it just works.

I love statistics, so the hourly, daily, weekly, monthly and yearly charts on the Nike website are great.  I can … Read More »


No Video Card Upgrade this round: No compelling reason

Gaming, News, Tech. Comments Off on No Video Card Upgrade this round: No compelling reason

15th November

No Video Card Upgrade this round: No compelling reason

AMD recently came out with their reference design for the R9 series of video cards (Hawaii Chipset): R9 Video Cards Overview .  I have read the reviews and the benchmarks, including comparisons to the 7990, GTX690 and Titan.  I see no compelling reason to “upgrade” my GTX690.  In fact, based on the benchmarks and reviews I have read GTX690 to R9 290X is more of a downgrade in power consumption, noise and mulit-monitor (2560 x 1600 X3) performance.  Crossfire is out of the question, since it does not support individual monitor color calibration, and I don’t even want to think about the TDP of such a setup.

I have looked through many benchmarks which have the GTX690 and HD7990 in the top spot for most games at the resolution I mentioned above.  The … Read More »


New Vacuum tube box scans

Site Updates, Tech, Vacuum Tubes. Comments Off on New Vacuum tube box scans

29th October

New Vacuum tube box scans

I have added several new images to my gallery of Vacuum Tube Box Artwork.

The new images include Westinghouse, Tung-Sol and Quality Brand tube boxes.

 

Quality Brand Tube Box Side 2

Westinghouse TV Receiving Tube Box Side (4)

 

Shaun M

 

 


New Section added: Vacuum tube glow, box scans and artwork

Site Updates, Tech, Vacuum Tubes. Comments Off on New Section added: Vacuum tube glow, box scans and artwork

27th October

New Section added: Vacuum tube glow, box scans and artwork

In the spirit of both preservation and exploration, I have added a new section to the the under Photography: Vacuum tube glow, box scans and artwork

Here I will be documenting the artwork used on vacuum tube boxes as well as showing some of the images I have captured of vacuum tubes while they are operating.  I will be adding more images over time as I work through my vacuum tube inventory.

 

12AU7 “Blue Glow”


Shaun Merrigan Landscape Photography Pages Updated

Photography, Site Updates. Comments Off on Shaun Merrigan Landscape Photography Pages Updated

26th October

Shaun Merrigan Landscape Photography Pages Updated

I have updated my Landscape Photography pages:  Shaun Merrigan: Landscapes from the Heart  Here are a couple of samples:

Sunrise at Raley

Alberta Prairie Sunrise

As well as my professional photography (Metallography, Scientific Photography) I am an avid landscape photographer. I work in medium format film and digital, and I prefer to explore the lonely and forgotten places on the Alberta and Saskatchewan prairies.

Shaun M.


Cubic Communications CDR-3250 VLF-HF Communications Receiver Fan Noise Solution Part II

Premium Receivers, Tech. Comments Off on Cubic Communications CDR-3250 VLF-HF Communications Receiver Fan Noise Solution Part II

12th October

Cubic Communications CDR-3250 VLF-HF Communications Receiver Fan Noise Solution Part II

This post will furnish additional detail about installing a quieter and more efficient rear panel fan in the Cubic Communications CDR-3250 VLF-HF Communications Receiver.

As I mentioned in the previous post, the duct/standoff/adapter can be made from wood. I chose solid pine because I had some in my offcuts box; plywood would be a good choice too.

The dimensions of the duct are: 75mm H x 60mm W x 15mm D as shown:

The holes are 55mm diameter (fan side) and 45mm diameter (receiver grille side). The hole on the receiver side had to be smaller in order to accommodate the 42mm bolt hole pattern of the OEM fan, while leaving enough material around the fastener holes for a sound mechanical joint. In addition, I happened to have 45mm and 55mm hole saws … Read More »


Cubic Communications CDR-3250 VLF-HF Communications Receiver Fan Noise Solution

Premium Receivers, Tech. Comments Off on Cubic Communications CDR-3250 VLF-HF Communications Receiver Fan Noise Solution

9th October

Cubic Communications CDR-3250 VLF-HF Communications Receiver Fan Noise Solution

I recently had the opportunity to acquire a Cubic Communications CDR-3250 VLF-HF Communications Receiver (two, in fact), fully functional, in very good condition. This is a very high quality, mil-spec receiver using DSP for the final IF, giving a large selection (51 possible, depending upon the mode) IF filters. It is stable, selective and has one of the best menu systems I have used in a receiver. Also the the audio quality and audio recovery is the best I have heard this side of a tube radio like the R390A or SP600JX. Oh yes, stereo headphones work (mono in both ears) properly from the headphone jack.

The receiver incorporates a small box fan in the rear of the chassis to pull air through cooling the modules and power supply (also at the rear). … Read More »


Windows Update Breaks Windows 7 Media Center Extender

News, Tech. Comments Off on Windows Update Breaks Windows 7 Media Center Extender

30th July

Windows Update Breaks Windows 7 Media Center Extender

This is a follow-up to my post regarding restoring Windows 7 Media Center after having problems with a couple of patches from Microsoft.
After restoring the WMC7 PC, most functions worked correctly, with the exception of:

1) TV Archive (it was working but failed on every file due to incorrect file permissions)
2) WHS 2011 did not longer see the restored WMC7 PC as a client, therefore automatic backups did not work, and the Lauchpad indicated that the WHS 2011 server was offline (it was not)
3) Some files, notably Recorded TV files, were no longer accessible from the WMC7 PC or from Extenders.

All of these issues were solved by performing the following steps:

1) Uninstall and then re-install the Extenders
2) Uninstall and then re-install the WHS 2011 connector software on the restored WMC7 PC
3) Make sure … Read More »


Windows Update Breaks Windows 7 Media Center Extender

News, Tech. Comments Off on Windows Update Breaks Windows 7 Media Center Extender

20th July

Windows Update Breaks Windows 7 Media Center Extender

The second Tuesday of the month has passed and Microsoft released another round of updates, fixing some critical vulnerabilities.

A summary of the July 9, 2013 update can be found here: http://technet.microsoft.com/en-us/security/bulletin/ms13-jul

It turned out that my Windows 7 64-bit WMC (Windows Media Center) PC had 17 updates available.  I applied all the updates, rebooting as required, and everything seemed to be running fine.

Unfortunately, I found that two of the patches had adverse effects on my WMC (Windows Media Center) Extenders.  Specifically, the Extenders (Xbox 360) would boot into Media Center and then report a “Connection Failure” , reboot into Media Center, report a Connection Failure, etc,  thus rendering them unusable.

After doing a system image restore to return the PC to its pre July 9 patch state (I have been down this road before), I … Read More »


Audible: Get it to work with WMP, Sonos and iTunes

News, Tech. Comments Off on Audible: Get it to work with WMP, Sonos and iTunes

24th March

Audible: Get it to work with WMP, Sonos and Itunes

I recently looked into joining Audible again after a hiatus of several years.  Looking at the greatly expanded catalog, and the new owner (Amazon), I decided to take the plunge.  My goal was to have all the audio books available on all my devices: Audible, Windows Media Player, my  iPads and Sonos.  The good news is that this can be done, but the process is not straightforward. There are a number things to watch out for:

Only use Audible Audio Format 4 for replay on all of the above devices. This is the highest quality that is available on all the devices.  The “e” format sounds better, but will not play on Sonos or WMP
You need two pieces of software from Audible: the Audible Manager, and the Audible Download Manager.  It is … Read More »


NEST Thermostat Functioning Well after Wiring Change

NEST Thermostat, News, Tech. Comments Off on NEST Thermostat Functioning Well after Wiring Change

16th March

NEST Thermostat Functioning Well after Wiring Change:

Over a month on since I changed my NEST v1 thermostat wiring to include the “C” or 24Vac Common wire, it is working flawlessly again. We have had several cycles of cold (-20C) and warm (+8C) and there have been no problems with charge levels, network communication or connectivity.

I wonder why NEST does not strongly recommend the use of the “C” wire when it is so simple to install? BTW, if you are looking for a wiring diagram of your furnace and controller, check the back side of the access panel (Doh!!) on the furnace; it should be there.

I have e found a couple of very useful links for anyone in a similar situation and seeking a solution:

Adding a C wire to a Thermostat

When-Nest-needs-a-common-C-wire

Shaun M


HP Z3200 Photo Printer Scan Axis Drive Belt Replacement

Photographic Printing, Photography, Tech. Comments Off on HP Z3200 Photo Printer Scan Axis Drive Belt Replacement

15th February

HP Z3200 Photo Printer Scan Axis Drive Belt Replacement:

I recently had to replace the Scan Axis Drive Belt (otherwise known as the carriage belt) in my HP Z3200 Photo Printer. I use the printer several times per week, but the print volumes I do are relatively light, so the belt did not “wear” out. Instead, the elastomer (rubber) component of the belt which binds the Kevlar strands together began to deteriorate and eventually disintegrated completely. Not only did this affect the Scan Axis alignment (see first image below) but it also left innumerable rubber crumbs throughout the paper path. I successfully replaced the belt and cleaned up the paper path and internals with a minimum of trouble, as well as replacing the noisy (howling) power supply fan. I should point out that I do have considerable background … Read More »


Gigapan Epic Pro Firmware Update Problems and Solution

Photography, Tech. Comments Off on Gigapan Epic Pro Firmware Update Problems and Solution

11th February

Gigapan Epic Pro Firmware Update Problems and Solution

Gigapan has a firmware update available for the GigaPan Epic Pro, here: GigaPan Epic Pro Firmware Update

To find out if you need it, check the firmware on your Epic Pro thus:

Select “Options” – “Expert Options” – “Firmware Version”
The current firmware version is P010100171-8.

I have a couple of very important tips for Windows users (Windows 7, specifically) which will help prevent any disasters from occurring (i.e., a botched firmware upgrade which will result in a dead Epic Pro):

1) Install the Firmware Upload Tool “As an Administrator”
2) Connect the USB cable from the Epic Pro directly to the motherboard, not to a hub or to the front panel USB ports on your PC. Not doing this caused my Epic Pro to lockup and not be recognized by Windows.
3) Run the Firmware Upload Tool “As an … Read More »


Nest thermostat battery charging problem and solution

News, Tech. Comments Off on Nest thermostat battery charging problem and solution

7th February

Nest thermostat battery charging problem and solution

My NEST (Generation 1) had been working flawlessly for several months, both summer and winter (heating and cooling) until about January 23rd, 2013 or so. Then it began to struggle with recharging, had network dropouts, disconnects, and began to insert Delay Times (apparently randomly, and up to 2 minutes in duration) into the heating cycle. I recharged the NEST using the USB interface a couple of times, only to find that it would run down within 8 or 10 hours and never recharge. With -25c temperatures for days on end, the last thing you want are strange delays and the resultant furnace cycle down/up and an unreliable thermostat. In fact one day with -40c windchill, the furnace would run for about 10 minutes and then cycle off as NEST inserted a Delay Time for … Read More »


GPS Clock Data Reset

News, Tech. Comments Off on GPS Clock Data Reset

5th January

GPS Clock Data Reset: I rebuilt the equipment rack that holds my network gear, HPZ3801A GPS Disciplined Clocks and the Zotac micro PC’s that run the associated software. The result is that there have been several interruptions to the data stream which I upload and display here. So I reset the log files, and restarted the logging from zero. The good news is that all the critical equipment now has UPS backup, so in addition to delivering clean power to the devices, short interruptions in the mains will not cause the clocks to reset.


Mass Effect 3 Omega DLC

Gaming, Tech. Comments Off on Mass Effect 3 Omega DLC

24th December

Mass Effect 3 Omega DLC

I played through “Omega” last night and I thoroughly enjoyed the experience. There are new adversaries and weapons, and if you choose to take them on you will have a blast. I have read reviews about this DLC suggesting it was shallow and lacked focus. Well, I guess it depends upon how deeply you have explored your relationship with Aria in ME2 and ME3. I committed to helping her in ME2, and she (at least) respects my choices. I wish I could have recruited Nyreen along with Garrus earlier on….


Flickr Christmas Gift

News, Photography. Comments Off on Flickr Christmas Gift

22nd December

For anyone who may be a Flickr Pro user, Flickr is giving a three-month extension to Pro accounts. When you sign in, you will be presented with a window to click through and accept the gift.

Merry Christmas!

Shaun Merrigan


NEST Thermostat Update

News, Tech. Comments Off on NEST Thermostat Update

21st December

NEST Thermostat Update

From November 30 to December 12 we had no wired internet connection. Therefore the NEST thermostat could not connect to NEST.com via our network. I found I had to turn off the NEST’s network connection so that it would not run down its internal battery constantly trying to connect to a non-existent network (Note: to the NEST team; this should be addressed). At no time did I ever lose local control, however. The NEST simply behaved like a typical sophisticated programmable thermostat. We have been experiencing one of the coldest winters in the last few years, so I can readily appreciate the very useful features of the NEST such as: tweaking the temperature from my iPad, making schedule adjustments via the iPad and viewing our energy usage.


Internet Connectivity Restored

News, Site Updates, Tech. Comments Off on Internet Connectivity Restored

19th December

Internet Connectivity Restored: Our Internet connectivity has been fully restored. After a couple of hiccups scheduling the installation, and some effort required to reconfigure my new DSL modem, I am reconnected and back online. We now have a VDSL 25Mbps down / 2Mbps up connection with no caps. In fact, I am getting 24.5Mbps down and 2.6Mbps up consistently. Streaming video, gaming, etc are easily handled with this speed. My NEST thermostat is connected to NEST.com again, and my weather station is fully back online, as are my GPS Disciplined Clocks. Photography updates will follow.


Internet Connectivity Update

News, Site Updates. Comments Off on Internet Connectivity Update

30th November

Internet Connectivity Update: iPad saves the day

Due to the hot economy hereabouts (cannot schedule the technicians), my DSL upgrade has been delayed somewhat. But I had to terminate my existing DSL service in order to obtain an activation date, thus I have no high speed internet. However I can used my iPad as a roving USB connected hotspot (no bluetooth or wireless, thanks) in order to edit, update, get mail, etc. It is a kludge, but a secure and stable one until my 25/2 DSL is activated.

My internal home gigabit wired network remains fully operational, of course, so everyone is happy talking to each other and various devices; they just have no outside connection.


Internet Connectivity Issues Update

News, Site Updates, Tech. Comments Off on Internet Connectivity Issues Update

28th November

Update to my ongoing Internet Connectivity Issues:

My ancient Zoom X4 DSL modem finally packed it in. I could not stand the connection dropping anymore, so I reconfigured my new ISP’s VDSL modem to work with my current (6MBps) connection. Naturally it is working fine.

This connection is due to terminate tomorrow and my new 25/2 connection will be activated. (Of course I saved the modem configuration, why do you ask?)

So with a bit of luck, I will be back on Friday.


Internet Connectivity Issues

News, Site Updates, Tech. Comments Off on Internet Connectivity Issues

18th November

I am currently in the process of resolving internet connectivity issues that I am experiencing.

I am also taking this opportunity to switch ISP’s because my current ISP does not offer any residential ASDL beyond 6Mbps. I am switching to Teksavvy and trying their high speed (25Mbps) ASDL plan. Of course this means a new modem and a line speed change which will solve the connectivity issues too. I am about 800 meters or so from the CO, and should have no problem with 25Mbps ADSL.

What this means is that some of my pages (Weather Station, Cams, Clocks) may not be updated as frequently as expected.

I will update this blog as I work through the process.

Shaun M.


NEST Thermostat Update

Tech. Comments Off on NEST Thermostat Update

16th November

NEST Thermostat Update

Winter is certainly here now, and the NEST thermostat has been performing well. I have had some issues with my ISP and DSL modem which have prevented the NEST thermostat from connecting to the web for 12 or more hours, but local control has been maintained throughout. This is a good sign, and indicative of well thought out design. I have a V1 Nest, which does not include humidity control. However, I think that my solution: a dedicated humidity controller with an external temperature sensor is probably superior anyway. In my cold climate, we absolutely need an air intake temperature sensor to regulate the humidity. Think about this at -25C….

My gut feeling is that my house is more evenly warm now that in was with the conventional programmable thermostat (Honeywell) that I … Read More »


IE9 Problems IE10 Joy

News, Tech. Comments Off on IE9 Problems IE10 Joy

16th November

IE9 Problems IE10 Joy

I was experiencing the dreaded blank page problem with IE9: at some point during the day, newly opened pages appear blank. There is no solution but rebooting the machine, and nobody knows why. (I have tried all the posted solutions short of reinstalling Windows 7).

The good news is that whatever the problem was, installing the IE10 preview has solved it. No blank pages, crashes, hangs, or issues. I had nothing to lose because the “blank page” problem had apparently infected IE9 64 bit, which I had previously thought to be immune.

To my surprise and delight, 1Password is working fine in IE10, and I have turned off all the third party tracking cookies too.

I should make here a general comment about Windows 7. I am running Win 7 Ultimate … Read More »


RAID 6 Server using 3TB Western Digital Reds

Tech. Comments Off on RAID 6 Server using 3TB Western Digital Reds

16th November

RAID 6 Server using 3TB Western Digital Reds:

The WD Reds are performing admirably; not a glitch or hiccup since the install. They are fast, amazingly quiet and reliable in 8 x 3TB RAID 6. I note that Adaptec is still not officially supporting this drive, but the Adaptec 6805 is working fine with 8 x 3TB Reds in RAID 6. All systems nominal.


Western Digital Reds Arrive, but Promise let me down

News, Photography, Tech. Comments Off on Western Digital Reds Arrive, but Promise let me down

10th October

I finally received my shipment of Western Digital Red 3TB Hard Drives which I had initially ordered in mid-August. I had thought that installing several of these drives in my Windows Home Server box would be a simple way to increase my RAID 6 storage space. Alas, I found out the hard way that my Promise Supertrack EX8760T RAID controller does not recognize WD 3TB drives and thus sees the WD Reds as 946GB, Sata II drives. In fact, they are 3TB, Sata III capable drives. A few emails exchanged with Promise Tech Support left me quite disappointed. In a nutshell, the Promise Supertrack EX8760T does not support 3TB drives, and there are no plans to support these drives in the future. Too bad, since the EX8760T is quite a robust card, and it has … Read More »


Nest Thermostat Update

News, Tech. Comments Off on Nest Thermostat Update

10th October

I was pleasantly surprised to see that my NEST Gen 1 thermostat updated itself to the latest software (V3) last week. This added a couple of new features like filter change reminder based on hours of use(forced air heating), energy use comparisons to similar house builds, Early On, Auto Schedule in Heat/Cool mode and several other new features. This is the same software that was rolled out with the Gen 2 Nest Thermostat, so I am not feeling left behind.

There were no issues transitioning from cooling season to heating season. We typically have 4-6 weeks in the fall and again in the spring where heating and cooling is not required, and we are just now getting into the heating season. I have had no issues at all with the NEST: Network connectivity has been … Read More »


Dell 30″ Ultrasharp on sale

News, Photography. Comments Off on Dell 30″ Ultrasharp on sale

23rd August

Dell has their 30″ IPS Panel monitor on sale for $300 off. I have two of these and just bought another. This is a vastly under-rated monitor for photography (once calibrated) and it is great for gaming as well. Don’t miss this.


NEST Thermostat update

News. Comments Off on NEST Thermostat update

17th July

The NEST thermostat has been operating faultlessly since I did the wiring reseat and SSID fix. We have had some very hot weather and I have been using the AWAY/AUTO AWAY modes, so I really appreciate being able to remotely cool the house down before arriving home. I also received an email from NEST showing me my cooling usage for the month of June. In aggregate, over time, this information will be very useful.

I am just finishing up the installation of a digital humidistat as the NEST has no provision for controlling humidity. I knew this before purchasing it, of course. I needed to upgrade my old wall mounted mechanical humidistat to a digital unit with a remote sensor on the fresh air intake in any case. This is particularly important in a cold … Read More »


Weather Station Tweaks and Updates

Site Updates. Comments Off on Weather Station Tweaks and Updates

24th June

I have completed several updates and tweaks to my Kildare Neighborhood Back Yard Weather Station:

Cumulus Software updated to v 1.9.3; most of the changes are under the hood.
Gauge Display page tweaked to a tidy 3×3 layout; this looks much better.
Web Cam repositioned for a better sky view and color images.

Shaun Merrigan


NEST Thermostat

News. Comments Off on NEST Thermostat

24th June

Further updates on my experiences with the NEST thermostat:

Although it is possible to enter a Canadian Postal Code using the NEST itself, I found that I could only change the geographic location ( City, Province) using the WEB app. The geographic location could not be changed using the iOS NEST app either, as that option is not made available. Having said all of that, once I made the changes using the WEB app, the proper location appeared on my NEST thermostat.

Had a problem earlier in the week with the NEST dropping my wifi connection and the battery not recharging. I did two things which solved the problem: first I reconnected all of the thermostat wires by pulling them out of the base plate (while pressing the release) and then pushing them back (not touching the release) to make sure … Read More »


NEST Thermostat

News. Comments Off on NEST Thermostat

2nd June

I installed a NEST learning thermostat (www.nest.com) this weekend.  No issues with the installation on my 2 stage heating 1 stage cooling, forced air HVAC system. I tested both heating and cooling and all worked fine. There are several problems which I have solved which may help other people who decide to install the NEST themselves:

1) The NEST will not behave as expected if the battery voltage is <3.7 volts.  For example, I thought that the proximity sensors were not functioning, and that I had some obscure network connectivity issues upon first installing the NEST. The NEST would not dectect me as I approached it (approach detection enabled) and kept dropping my network connection.  It turned out that ALL of these problems were related to the battery voltage being < 3.70 volts.

2) I could have waited several hours for the … Read More »


shaunmerrigan.info updated

News. Comments Off on shaunmerrigan.info updated

8th April

I have completely rebuilt the site; it is now based on WordPress rather than uploaded HTML code.

I have basically massaged a WordPress theme me into more of a website and less of a blog.  But this suits my purpose for the site, which is primarily a way to view my back yard weather station information and GPS clock data.